ASTM D4417 METHOD C PDF

ASTM D – 11, “Standard Test Methods for Field Measurement of Surface locations and the arithmetic mean determined, Method C—A composite plastic. ASTM D, Standard Test Methods for Measurement of Surface Profile of Blast Appendix C: Additional Considerations when Measuring Surface Profile. ASTM D – 11 Standard Test Methods for Field Measurement of Surface Profile of Blast Method C—A composite plastic tape is impressed into.

Author: Negul Guzragore
Country: Bahamas
Language: English (Spanish)
Genre: Automotive
Published (Last): 2 August 2006
Pages: 110
PDF File Size: 3.38 Mb
ePub File Size: 7.71 Mb
ISBN: 318-5-48211-668-2
Downloads: 53575
Price: Free* [*Free Regsitration Required]
Uploader: Nijas

Both the structure and the coating system protecting the structure will move while in service. Pull-Off Adhesion of Coatings on Concrete As stated above, the original version of D published in did not distinguish between testing the pull-off strength of coatings applied to steel versus concrete surfaces. Work Item s – proposed revisions of this standard. Conversely, concrete is a heterogeneous substrate.

Your email address will not be published. The instruments described are readily portable and sufficiently sturdy for use in the field.

William D. Corbett KTA-Tator, Inc. – ppt video online download

With the base of the micrometer resting on the peaks of the surface profile, and the conical pin protruding to a valley of the profile, the distance is read from the gage display in mils or micrometers. Typically, the higher the coating thickness the greater the surface profile depth. This is done because of evidence that coatings performance in any one astm d method c area is primarily influenced by the highest surface features in that area and not by the average roughness.

  ERITRODERMIA ATOPICA PDF

However, thick film coatings i. This method encompasses only one surface characteristic: Pull-Off Adhesion of Coatings The adhesion of a protective coating is a critical attribute that is related to performance. Originally approved in Conceptually, the study will include two types of concrete normal and high strengthtwo coatings thick film with scoring and thin-film without scoringfive types of adhesion testers and up to seven laboratories.

As a result, there are differences in testing procedures that should be considered when evaluating coatings applied to concrete, versus coatings applied to steel.

Steel is a fairly homogeneous substrate and its tensile strength does not vary from test site to test site. The distance between the highest peak and the lowest valley within any given evaluation length Rmax: With the base of the micrometer resting on the peaks of the surface profile, and the conical pin protruding to a valley of the profile, the distance is read from the gage display in mils or micrometers. Standards for Measurement of Surface Profile.

Differences in Surface Profile Measurements: ASTM D4417- Method B vs. Method C

Download ppt “William D. Additional Considerations when Measuring Surface Profile. Aetm D contains three methods of measuring surface profile depth: Adjust the instrument to zero.

Locations of tests; test method s ; test results; conformance to specification The magnitude of the non-conforming surface profile measurement areas must be determined, marked and recorded as described earlier. Surface Chloride Extraction and Analysis The protective coatings industry has long recognized the potential consequences of coating over soluble salts i.

Share buttons are a little bit lower. Method Methoe replica tape employs a pressure sensitive tape containing a compressible foam attached to a polyester backing to replicate the peak-valley pattern generated by the abrasive blast cleaning process. The pattern of surface roughness is s4417 by burnishing the tape, effectively pressing the compressible foam into the surface roughness. The measurements must conform to the minimum and maximum surface profile requirements listed in the project specification.

  ETHNOCULTURAL TRANSFERENCE AND COUNTERTRANSFERENCE IN THE THERAPEUTIC DYAD PDF

Soluble salts like chloride, when astm d method c beneath a newly applied coating, can draw water through the coating film by a process known as osmosis and cause blistering and underfilm corrosion. An interlaboratory research initiative for the purpose of generating precision and bias statements for Dis planned for Do not drag the instrument across the surface between readings, or the spring-loaded tip may become rounded leading to false readings.

Early detection and removal of appreciable amounts of surface chloride contamination prior to coating installation can prolong the service life of a coating, reducing the frequency of maintenance painting and reducing life cycle costs. Some of the coatings are applied up to 3. How can I make my job easier?

The base of the instrument rests on the peaks of the surface profile while the cone-shaped point projects into the valley. Summary of Test Method 2. Models from a few gage manufacturers are available that conform to this standard.

This movement may be caused by expansion and contraction of the substrate due to temperature fluctuation, or live loads placed onto a structure; for example, traffic crossing a bridge.

Models from a few gage manufacturers are available that conform to this standard.